|
 |
Price
List
December 2009 |
Accessories
for LPG Systems
Liquid Transfer Pumps
AEP-Series
|
|
Return
to Main Price List Page |
Download complete Price List as
PDF file |
|
|
LPG
Transfer Pumps
LPG Transfer Pumps, as the name
implies, are used to transfer LPG from the storage tanks to the
vaporizer. In systems with venturi LPG/air mixing systems, they are also
responsible for maintaining the pressure needed for optimum and
efficient function of the venturi mixers.
AES
uses pumps from the two leading manufacturers, Blackmer and Corken.
All
pumps are mounted on steel skids, and are primed and painted. They are
equipped with constant pressure regulator, strainer, isolation valves,
summer bypass loops, liquid filled pressure gauges, and other components
that are required for safe operation.
Smaller
pumps up to 23/26 GPM are for single phase AC115/230V 60Hz service.
Larger pumps are for 3-phase AC230/460V 60Hz and require external motor
starters. All pumps are also available for 50Hz service (AC230V 50Hz
single phase; AC380/400/415V 50Hz 3-phase). Pumps up to 31 GPM are
direct drive pumps (electric motor directly coupled to pump). Larger
pumps are belt driven.
Dual
Pump Systems are manufactured as two single pumps. Except for the common
skid, they do not share any essential components (maximum redundancy).
The pumps in dual pump systems can be used in any combination: Pump 1,
Pump 2, or Pump 1 and Pump 2 together.
If pump
systems are integrated with the vaporizer or vaporizer/blender controls,
a start/stop station in an explosion-proof enclosure is installed
directly at the pump skid. Integrated pumps can also be equipped with an
automatic start/stop function in response to the pressure in the storage
tank(s). The price adder for these options is shown below (in the “Motor
Starters” section). |
|
|
Blackmer
Pump Packages |
|
Model
Number |
Capacity |
Max.
System
Size
MMBTU/h |
Pump
Type |
Motor
HP/RPM |
Electrical
Supply |
Price
in US-$
Single
Pump
Package |
Price
in US-$
Dual
Pump
Package |
| AEP-
5B |
5 gpm |
10 |
LGF1 |
1.0/1750 |
AC 115/230 V 1-Phase |
$8,564 |
$15,134
|
| AEP-
9B |
9 gpm |
20 |
LGF1P |
1.5/1750 |
AC 115/230 V 1-Phase |
$9,132 |
$16,274
|
| AEP-15B |
15 gpm |
30 |
LGL1.25 |
3.0/1750 |
AC 230/460 V 3-Phase |
$9,797 |
$17,602
|
| AEP-23B |
23 gpm |
50 |
LGL1.5 |
3.0/1750 |
AC 230/460 V 3-Phase |
$11,603 |
$20,529
|
| AEP-45B1 |
45 gpm |
100 |
LGL2 |
5.0/520 |
AC 230/460 V 3-Phase |
$18,541 |
$30,459
|
| AEP-58B1 |
58 gpm |
130 |
LGL3 |
7.5/420 |
AC 230/460 V 3-Phase |
$21,806 |
$36,307
|
| AEP-75B1 |
75 gpm |
160 |
LGL3 |
10/520 |
AC 230/460 V 3-Phase |
$22,489 |
$37,676
|
| AEP-112B1 |
112 gpm |
240 |
LGL4 |
15/420 |
AC 230/460 V 3-Phase |
$33,772 |
$60,221 |
| AEP-150B1 |
150 gpm |
300 |
LGL4 |
15/520 |
AC 230/460 V 3-Phase |
$33,772 |
$60,221 |
|
1 Belt driven
Pump. Specifications are subject to change without notice.
Call factory
or distributor for price quotation and actual lead times. |
|
|
|
|
Corken
Pump Packages |
|
Model
Number |
Capacity |
Max.
System
Size
MMBTU/h |
Pump
Type |
Motor
HP/RPM |
Electrical
Supply |
Price
in US-$
Single
Pump
Package |
Price
in US-$
Dual
Pump
Package |
| AEP-12C |
12 gpm |
25 |
C12 |
1.0/3450 |
AC 115/230 V 1-Phase |
$9,235 |
$16,238 |
| AEP-16C |
16 gpm |
30 |
C13 |
2.0/3450 |
AC 115/230 V 1-Phase |
$10,136 |
$18,037 |
| AEP-26C |
26 gpm |
50 |
C14 |
3.0/3450 |
AC 230/460 V 3-Phase |
$10,744 |
$19,251 |
| AEP-29C1 |
29 gpm |
60 |
521 |
3.0/430 |
AC 230/460 V 3-Phase |
$17,792 |
$19,251 |
| AEP-40C1 |
40 gpm |
80 |
521 |
5.0/520 |
AC 230/460 V 3-Phase |
$18,211 |
$31,166 |
| AEP-53C1 |
53 gpm |
110 |
521 |
5.0/640 |
AC 230/460 V 3-Phase |
$18,211 |
$31,166 |
| AEP-60C1 |
60 gpm |
130 |
521 |
7.5/350 |
AC 230/460 V 3-Phase |
$22,465 |
$39,673 |
| AEP-68C1 |
68 gpm |
150 |
1021 |
10/350 |
AC 230/460 V 3-Phase |
$23,150 |
$41,044 |
| AEP-80C1 |
80 gpm |
200 |
1021 |
10/420 |
AC 230/460 V 3-Phase |
$23,150 |
$41,044 |
| AEP-108C1 |
108 gpm |
240 |
1021 |
15/520 |
AC 230/460 V 3-Phase |
$24,299 |
$41,972 |
| AEP-132C1 |
132 gpm |
300 |
1521 |
15/420 |
AC 230/460 V 3-Phase |
$33,433 |
$59,614 |
|
1 Belt driven
Pump. Specifications are subject to change without notice.
Call factory
or distributor for price quotation and actual lead times. |
|
|
|
|
|
Motor Starter Packages for 3-Phase Pumps (fits both Blackmer and Corken
Pumps) |
|
Description |
Voltage |
3
HP |
5
HP |
7.5
HP |
10
HP |
Allen-Bradley
Starter Package, Non-Explosion- Proof, NEMA 1 Indoor Enclosure;
Start/Stop Station;
supplied loose for field installation. |
AC 230 V |
$1,109.00 |
$1,153.00 |
$1,153.00 |
$1,153.00 |
| AC 480 V |
$1,153.00 |
$1,153.00 |
$1,153.00 |
$1,153.00 |
Allen-Bradley
Starter Package, Non-Explosion- Proof, NEMA 3R Outdoor Enclosure;
Start/Stop Station;
supplied loose for field installation. |
AC 230 V |
$1,395.00 |
$1,468.00 |
$1,468.00 |
$1,468.00 |
| AC 480 V |
$1,468.00 |
$1,468.00 |
$1,468.00 |
$1,468.00 |
| Installation
of Non-Explosion-Proof Motor Starter on the Inside or the Outside of a
Vaporizer Control Room. |
AEP-INS-1
$929.00 (per Starter Package) |
Allen-Bradley
Starter Package, Explosion-Proof, NEMA 7,9,3R Outdoor Enclosure;
Start/Stop Station;
supplied loose for field installation. |
AC 230 V |
$3,261.00 |
$3,349.00 |
$3,349.00 |
$3,349.00 |
| AC 480 V |
$3,349.00 |
$3,349.00 |
$3,349.00 |
$3,349.00
|
| Installation
of Explosion-Proof Motor Starter on Pump Package (includes mounting
frame and explosion-proof Flex-Conduit)
|
AEP-INS-2
$2,047.00 (per Starter Package) |
Integration of
pump control in vaporizer or vaporizer/blender control system;
includes remote start/stop station in ex-proof enclosure, installed at
pump skid. |
$2,664.00 |
|
Automatic pump start/stop
in response to pressure in storage tank(s); includes option “integration
of pump control in vaporizer or vaporizer/blender control system”;
includes Rosemount pressure transmitter in pump inlet. |
$5,578.00 |
|
All
Starter Packages consist of the motor starter (appropriately sized for
the selected pump motor), integrated Start/Stop station, heater strips,
and an enclosure. “Standard” configurations are available for indoor
or outdoor installation in a non-hazardous area (such as the vaporizer
control room); “Ex Proof” configurations are designed for
installation at the pump location. Factory installation of ex-proof
starter packages includes a mounting frame attached to the pump skid,
and ex-proof flexible conduit between the enclosure and the pump. Dual
Pump Packages require 2 identical Starter Packages. |
|
|
|
|