Price
List
June 2011 |
Accessories
for LPG Systems
Liquid Transfer Pumps
AEP-Series
|
|
Return
to Main Price List Page |
Download complete Price List as
PDF file |
|
|
 |
Pump System Features
Quick-Select Chart for
AES Vaporizers / AES Pumps
Pump Selection Charts:
|
LPG Transfer Pumps, as the
name implies, are used to transfer liquid LPG from the storage tanks to
the vaporizer. In systems with venturi LPG/air mixing systems, they are
also responsible for maintaining the pressure needed for optimum and
efficient function of the venturi mixers.
AES uses pumps from the
two leading manufacturers, Blackmer and Corken.
All pumps are of "positive displacement" design and use rotary vane pumps with a built-in over-pressure relief valve, designed for continuous use with high reliability.
All pumps are mounted on
steel skids, and are primed and painted. They are equipped with constant
pressure regulator, strainer, isolation valves, summer bypass loops,
liquid filled pressure gauges, and other components that are required
for safe operation.
All systems are supplied with an explosion proof motor to meet Class I, Div. 1, Group D
[Flame-Proof] requirements, and are available for 60Hz service or for
50Hz service and for various voltages. Smaller pumps are for single
phase service. Larger pumps are for 3-phase service and require magnetic
motor starters. When sizing a
pump system, the nominal pump capacity should be approximately twice the
nominal capacity of the LP or LP/Air system. Nominal pump capacities may
vary with type of LPG, ambient conditions, available electric service,
required discharge pressure, and other factors.
Blackmer pumps up to
model AEP-12B, and Corken pumps up to model AEP-18C, are direct-drive
pumps (electric motor directly coupled to pump). Larger pumps are
belt-driven.
The purpose of Duplex Pump Systems is to provide
maximum redundancy. They are therefore manufactured as individual pumps
that only share a common skid. All
bypass and isolation valves exist in duplicate and allow using the pumps in any combination:
Pump 1, Pump 2, or Pump 1 and Pump 2 together. Each pump can be
completely isolated so that maintenance and repair work on this pump
does not affect the other pump, or the system availability.
Magnetic motor starters can be supplied either as separate components,
installed on the pump skid, or integrated with the system controls. If
pump systems are integrated with the vaporizer or vaporizer/blender
controls, a start/stop station in an ex-proof enclosure is installed
directly at the pump skid and provides local pump control.
Integrated pumps can also
be equipped with an automatic start/stop function in response to the
pressure in the storage tank(s). The price adder for these options is
shown below (in the “Motor Starters and other Options” section). |
|
|
|
|
Corken Pumps
Selection Chart
60Hz
All prices and specifications are
subject to change without notice. |
Direct-Driven |
Belt-Driven |
|
CF12
AEP-
05C |
CF13
AEP-
07C |
FF14
AEP-
11C |
FF150
AEP-
18C |
Z2000
AEP-
32C |
Z3500
AEP-
42C |
Z3500
AEP-
53C |
Z3500
AEP-
68C |
Z4500
AEP-
98C |
| Single
Pump System |
US-$
14,323 |
US-$
14,615 |
US-$
15,379 |
US-$
17,160 |
US-$
19,826 |
US-$
31,295 |
US-$
32,696 |
US-$
40,663 |
US-$
51,032 |
| Duplex
Pump System |
US-$
28,933 |
US-$
29,523 |
US-$
31,066 |
US-$
34,664 |
US-$
40,049 |
US-$
63,216 |
US-$
66,046 |
US-$
82,140 |
US-$
103,085 |
|
Maximum Vaporizer
Capacity [gph]
Maximum Vaporizer Capacity [kg/h]
(based on 100psi / 7 bar
discharge) |
Find "your" LPG type and the sample
operating conditions in the column on the far-left.
Move to the right until the shown value is equal to, or greater than,
the capacity of the vaporizer that is to be supplied by the pump.
Move up to identify the AES Pump Model Number. |
HD-5 Propane
Min.
Temperature 0°F / -18°C
ΔP 78 psi / 5.4 bar |
288
558 |
408
790 |
648
1254 |
1080
2091 |
1920
3717 |
2520
4878 |
3192
6179 |
4056
7852 |
5856
11336 |
HD-5 Propane
Min.
Temperature -40F / -40°C
ΔP 99 psi / 6.8 bar |
168
325 |
312
604 |
480
929 |
1008
1951 |
1872
3624 |
2280
4414 |
3000
5807 |
3936
7619 |
5784
11197 |
LPG with 50% Propane/50%Butane
Min.
Temperature 32°F / 0°C
ΔP 74 psi / 5.1 bar |
216
443 |
312
640 |
504
1034 |
696
1428 |
1176
2413 |
1656
3398 |
2064
4236 |
2520
5171 |
3576
7338 |
LPG
with 50% Propane/50%Butane
Min.
Temperature 15°F / -10°C
ΔP 82 psi / 5.7 bar |
192
394 |
288
591 |
456
936 |
696
1428 |
1176
2413 |
1584
3251 |
1992
4088 |
2496
5122 |
3552
7289 |
LPG
with 30% Propane/70%Butane
Min.
Temperature 32°F / 0°C
ΔP 84 psi / 5.8 bar |
144
303 |
216
454 |
336
707 |
480
1010 |
792
1666 |
1104
2323 |
1128
2373 |
1680
3534 |
2376
4999 |
| Electric
Motor |
220V 60Hz |
220V 60Hz or
460V 60Hz |
460V 60Hz |
|
Motor Type |
Single-Phase |
3-Phase
(all 3-phase motors require magnetic starters and overload protection)
|
|
Motor Protection |
Class I, Div 1, Group
D (Flame Proof) |
|
Motor Size [hp] |
2 |
3 |
5 |
7.5 |
7.5 |
10 |
15 |
20 |
25 |
|
Motor RPM |
3450 |
3450 |
3450 |
3450 |
750 |
520 |
640 |
780 |
520 |
| Pump
Connections |
All pump body
connections and all on-skid component connections are 300# RF ANSI.
All pump skid connections are 300# RF ANSI or DIN PN40 (PN25 for DN100
and above). |
|
Pump Body, Inlet |
1.5" |
1.5" |
1.5" |
1.5" |
2" |
3" |
3" |
3" |
4" |
|
Pump Body, Outlet |
1" |
1" |
1" |
1" |
2" |
3" |
3" |
3" |
4" |
|
Pump Skid, Inlet |
2"
DN50 |
2"
DN50 |
2"
DN50 |
2"
DN50 |
3"
DN80 |
4"
DN100 |
4"
DN100 |
4"
DN100 |
6"
DN150 |
|
Pump Skid, Outlet |
1"
DN25 |
1"
DN25 |
1"
DN25 |
1"
DN25 |
2"
DN50 |
3"
DN80 |
3"
DN80 |
3"
DN80 |
3"
DN80 |
|
|
|
Corken Pumps
Selection Chart
50Hz
All prices and specifications are
subject to change without notice. |
Direct-Driven |
Belt-Driven |
|
CF12
AEP-
05C |
CF13
AEP-
07C |
FF075
AEP-
11C |
FF150
AEP-
18C |
Z2000
AEP-
32C |
Z3500
AEP-
42C |
Z3500
AEP-
53C |
Z3500
AEP-
68C |
Z4500
AEP-
98C |
| Single
Pump System (US-$) |
|
US-$
15,243 |
US-$
16,500 |
US-$
17,758 |
US-$
20,455 |
US-$
32,058 |
US-$
33,472 |
US-$
41,643 |
US-$
52,015 |
| Duplex
Pump System (US-$) |
|
US-$
30,791 |
US-$
33,330 |
US-$
35,872 |
US-$
41,320 |
US-$
64,758 |
US-$
67,414 |
US-$
84,119 |
US-$
105,071 |
|
Maximum Vaporizer Capacity [gph]
Maximum Vaporizer Capacity [kg/h]
(based on 100psi / 7 bar
discharge)
|
Find "your" LPG type and the sample
operating conditions in the column on the far-left.
Move to the right until the shown value is equal to, or greater than,
the capacity of the vaporizer that is to be supplied by the pump.
Move up to identify the AES Pump Model Number. |
HD-5 Propane
Min.
Temperature 0°F / -18°C
ΔP 78 psi / 5.4 bar |
n/a |
192
372 |
528
1022 |
864
1673 |
1920
3717 |
2520
4878 |
3192
6179 |
4056
7852 |
5856
11336 |
HD-5 Propane
Min.
Temperature -40F / -40°C
ΔP 99 psi / 6.8 bar |
n/a |
72
139 |
432
836 |
768
1487 |
1872
3624 |
2280
4414 |
3000
5807 |
3936
7619 |
5784
11197 |
LPG with 50% Propane/50%Butane
Min.
Temperature 32°F / 0°C
ΔP 74 psi / 5.1 bar |
n/a |
192
394 |
384
788 |
600
1231 |
1176
2413 |
1656
3398 |
2064
4236 |
2520
5171 |
3576
7338 |
LPG
with 50% Propane/50%Butane
Min.
Temperature 15°F / -10°C
ΔP 82 psi / 5.7 bar |
n/a |
168
345 |
360
739 |
576
1182 |
1176
2413 |
1584
3251 |
1992
4088 |
2496
5122 |
3552
7289 |
LPG
with 30% Propane/70%Butane
Min.
Temperature 32°F / 0°C
ΔP 84 psi / 5.8 bar |
n/a |
120
252 |
240
505 |
384
808 |
792
1666 |
1104
2323 |
1128
2373 |
1680
3534 |
2376
4999 |
| Electric
Motor |
230V 50Hz |
400/415V 50Hz |
|
Motor Type |
Single-Phase |
3-Phase
(all 3-phase motors require magnetic starters and overload protection)
|
|
Motor Protection |
Class I, Div 1, Group
D (Flame Proof) |
|
Motor Size [hp] |
n/a |
3 |
5 |
7.5 |
7.5 |
10 |
15 |
20 |
25 |
|
Motor RPM |
n/a |
2880 |
2880 |
2880 |
750 |
520 |
640 |
780 |
520 |
| Pump
Connections |
All pump body
connections and all on-skid component connections are 300# RF ANSI.
All pump skid connections are 300# RF ANSI or DIN PN40 (PN25 for DN100
and above). |
|
Pump Body, Inlet |
n/a |
1.5" |
1.5" |
1.5" |
2" |
3" |
3" |
3" |
4" |
|
Pump Body, Outlet |
n/a |
1" |
1" |
1" |
2" |
3" |
3" |
3" |
4" |
|
Pump Skid, Inlet |
n/a |
2"
DN50 |
2"
DN50 |
2"
DN50 |
3"
DN80 |
4"
DN100 |
4"
DN100 |
4"
DN100 |
6"
DN150 |
|
Pump Skid, Outlet |
n/a |
1"
DN25 |
1"
DN25 |
1"
DN25 |
2"
DN50 |
3"
DN80 |
3"
DN80 |
3"
DN80 |
3"
DN80 |
|
|
|
Blackmer
Pumps
Selection Chart
60Hz
All prices and specifications are
subject to change without notice. |
Direct-Driven |
Belt-Driven |
|
LGF1
AEP-
03B |
LGF1P
AEP-
04B |
LGL1.25
AEP-
08B |
LGL1.5
AEP-
12B |
LGL2
AEP-
18B |
LGL3
AEP-
28B |
LGL3
AEP-
37B |
LGL4
AEP-
66B |
LGL4
AEP-
85B |
| Single
Pump System |
US-$
14,065 |
US-$
14,426 |
US-$
15,400 |
US-$
17,679 |
US-$
20,146 |
US-$
31,806 |
US-$
33,315 |
US-$
48,400 |
US-$
52,800 |
| Duplex
Pump System |
US-$
28,412 |
US-$
29,141 |
US-$
31,108 |
US-$
35,712 |
US-$
40,695 |
US-$
64,249 |
US-$
67,297 |
US-$
97,768 |
US-$
106,656 |
|
Maximum Vaporizer Capacity [gph]
Maximum Vaporizer Capacity [kg/h]
(based on 100psi / 7 bar
discharge)
|
Find "your" LPG type and the sample
operating conditions in the column on the far-left.
Move to the right until the shown value is equal to, or greater than,
the capacity of the vaporizer that is to be supplied by the pump.
Move up to identify the AES Pump Model Number. |
HD-5 Propane
Min.
Temperature 0°F / -18°C
ΔP 78 psi / 5.4 bar |
168
325 |
264
511 |
456
883 |
720
1394 |
1104
2137 |
1656
3206 |
2208
4274 |
3960
7666 |
5088
9850 |
HD-5 Propane
Min.
Temperature -40F / -40°C
ΔP 99 psi / 6.8 bar |
144
279 |
240
465 |
432
836 |
696
1347 |
1008
1951 |
1440
2788 |
1992
3856 |
3480
6737 |
4752
9199 |
LPG with 50% Propane/50%Butane
Min.
Temperature 32°F / 0°C
ΔP 74 psi / 5.1 bar |
120
246 |
192
394 |
288
591 |
456
936 |
744
1527 |
1128
2315 |
1440
2955 |
2640
5418 |
3336
6846 |
LPG
with 50% Propane/50%Butane
Min.
Temperature 15°F / -10°C
ΔP 82 psi / 5.7 bar |
120
246 |
168
345 |
288
591 |
456
936 |
696
1428 |
1080
2216 |
1416
2906 |
2520
5171 |
3240
6649 |
LPG
with 30% Propane/70%Butane
Min.
Temperature 32°F / 0°C
ΔP 84 psi / 5.8 bar |
72
151 |
120
252 |
192
404 |
312
656 |
480
1010 |
768
1616 |
960
2020 |
1752
3686 |
2232
4696 |
| Electric
Motor |
220V 60Hz |
220 or 460V 60Hz |
460V 60Hz |
|
Motor Type |
Single-Phase |
3-Phase
(all 3-phase motors require magnetic starters and overload protection)
|
|
Motor Protection |
Class I, Div 1, Group
D (Flame Proof) |
|
Motor Size [hp] |
1 |
1.5 |
3 |
5 |
7.5 |
10 |
15 |
20 |
25 |
|
Motor RPM |
1750 |
1750 |
1750 |
1750 |
520 |
420 |
520 |
420 |
520 |
| Pump
Connections |
All pump body
connections and all on-skid component connections are 300# RF ANSI.
All pump skid connections are 300# RF ANSI or DIN PN40 (PN25 for DN100
and above). |
|
Pump Body, Inlet |
1" |
1" |
1.25" |
1.5" |
2" |
3" |
3" |
4" |
4" |
|
Pump Body, Outlet |
1" |
1" |
1.25" |
1.5" |
2" |
3" |
3" |
4" |
4" |
|
Pump Skid, Inlet |
1.5"
DN40 |
1.5"
DN40 |
2"
DN50 |
2"
DN50 |
3"
DN80 |
4"
DN100 |
4"
DN100 |
6"
DN150 |
6"
DN150 |
|
Pump Skid, Outlet |
1"
DN25 |
1"
DN25 |
1"
DN25 |
1.5"
DN40 |
2"
DN50 |
3"
DN80 |
3"
DN80 |
4"
DN100 |
4"
DN100 |
|
|
|
Blackmer
Pumps
Selection Chart
50Hz
All prices and specifications are
subject to change without notice. |
Direct-Driven |
Belt-Driven |
|
LGF1
AEP-
03B |
LGF1P
AEP-
04B |
LGL1.25
AEP-
08B |
LGL1.5
AEP-
12B |
LGL2
AEP-
18B |
LGL3
AEP-
28B |
LGL3
AEP-
37B |
LGL4
AEP-
66B |
LGL4
AEP-
85B |
| Single
Pump System |
US-$
14,693 |
US-$
15,055 |
US-$
16,029 |
US-$
18,386 |
US-$
20,775 |
US-$
32,529 |
US-$
34,258 |
US-$
49,972 |
US-$
54,215 |
| Duplex
Pump System |
US-$
29,680 |
US-$
30,412 |
US-$
32,379 |
US-$
37,140 |
US-$
41,966 |
US-$
65,709 |
US-$
69,202 |
US-$
100,944 |
US-$
109,915 |
|
Maximum Vaporizer Capacity [gph]
Maximum Vaporizer Capacity [kg/h]
(based on 100psi / 7 bar
discharge)
|
Find "your" LPG type and the sample
operating conditions in the column on the far-left.
Move to the right until the shown value is equal to, or greater than,
the capacity of the vaporizer that is to be supplied by the pump.
Move up to identify the AES Pump Model Number. |
HD-5 Propane
Min.
Temperature 0°F / -18°C
ΔP 78 psi / 5.4 bar |
120
232 |
192
372 |
384
743 |
576
1115 |
1104
2137 |
1656
3206 |
2208
4274 |
3960
7566 |
5088
9850 |
HD-5 Propane
Min.
Temperature -40F / -40°C
ΔP 99 psi / 6.8 bar |
96
186 |
168
325 |
336
650 |
552
1069 |
1008
1951 |
1440
2788 |
1992
3856 |
3480
6737 |
4752
9199 |
LPG with 50% Propane/50%Butane
Min.
Temperature 32°F / 0°C
ΔP 74 psi / 5.1 bar |
120
246 |
144
296 |
264
542 |
384
788 |
744
1527 |
1128
2315 |
1440
2955 |
2640
5418 |
3336
6846 |
LPG
with 50% Propane/50%Butane
Min.
Temperature 15°F / -10°C
ΔP 82 psi / 5.7 bar |
120
246 |
144
296 |
240
493 |
360
739 |
696
1428 |
1080
2216 |
1416
2906 |
2520
5171 |
3240
6649 |
LPG
with 30% Propane/70%Butane
Min.
Temperature 32°F / 0°C
ΔP 84 psi / 5.8 bar |
72
151 |
96
202 |
168
353 |
240
505 |
480
1010 |
768
1616 |
960
2020 |
1752
3686 |
2232
4696 |
| Electric
Motor |
230V 50Hz |
400/415V 50Hz |
|
Motor Type |
Single-Phase |
3-Phase
(all 3-phase motors require magnetic starters and overload protection)
|
|
Motor Protection |
Class I, Div 1, Group
D (Flame Proof) |
|
Motor Size [hp] |
1 |
1.5 |
3 |
5 |
7.5 |
10 |
15 |
20 |
25 |
|
Motor RPM |
1450 |
1450 |
1450 |
1450 |
420 |
350 |
420 |
350 |
420 |
| Pump
Connections |
All pump body
connections and all on-skid component connections are 300# RF ANSI.
All pump skid connections are 300# RF ANSI or DIN PN40 (PN25 for DN100
and above). |
|
Pump Body, Inlet |
1" |
1" |
1.25" |
1.5" |
2" |
3" |
3" |
4" |
4" |
|
Pump Body, Outlet |
1" |
1" |
1.25" |
1.5" |
2" |
3" |
3" |
4" |
4" |
|
Pump Skid, Inlet |
1.5"
DN40 |
1.5"
DN40 |
2"
DN50 |
2"
DN50 |
3"
DN80 |
4"
DN100 |
4"
DN100 |
6"
DN150 |
6"
DN150 |
|
Pump Skid, Outlet |
1"
DN25 |
1"
DN25 |
1"
DN25 |
1.5"
DN40 |
2"
DN50 |
3"
DN80 |
3"
DN80 |
4"
DN100 |
4"
DN100 |
|
|
|
|
Motor Starters and Other Options for
Single-Phase Pumps (fits both Blackmer and Corken
Pumps) |
|
Liquid Transfer Pumps
with single-phase motors can be supplied with a simple, explosion-proof
ON/OFF switch that is integrated into the junction box directly at the
pump motor. If the pump control is desired to be integrated with the
vaporizer- or vaporizer/blender control system (for example to
facilitate remote monitoring and control), pumps with single-phase
motors can also be equipped with contactors.
It is recommended that contactor-equipped pumps are also equipped with a
local Start/Stop station that allows pump control from the pump
location. AES Start/Stop stations are configured with an explosion-proof
enclosure (Class I, Div 1, Group D [Flame-Proof]), green START button,
red STOP button, and amber pilot light (pump ready to be started).
The operation of single-phase pumps with contactors can also be
automated in response to the pressure in the storage tanks (pump will
start automatically if tank pressure falls below an adjustable setpoint,
and stays on until the tank pressure has recovered above a second
adjustable setpoint). |
|
|
Description (for
Single-Phase Motors) |
Single-Pump |
Dual-Pump |
|
Pump Contactor
for single-phase pumps, max. motor size 5HP; installed in
vaporizer- or vaporizer/blender control panel; terminals for AC
feed, pump connection, and control voltage. |
US-$
769 |
US-$
1,385 |
|
Pump
Contactor for single-phase pumps, max. motor size 5HP; installed
in separate enclosure;
supplied loose for indoor field
installation (NEMA 1).
|
US-$
1,077 |
US-$
1,938 |
|
Pump
Contactor for single-phase pumps, max. motor size 5HP; installed
in separate enclosure;
supplied loose for outdoor field
installation (NEMA 3R). |
US-$
1,399 |
US-$
2,260 |
|
Start/Stop Station, Explosion-Proof Class I Div 1
Group D [Flame Proof]; installed in separate enclosure; green
START button; red STOP button;
amber Pilot Light; supplied loose
for field installation at pump location (NEMA 7, 9, 3R Ex-Proof
Outdoor Enclosure). |
US-$
1,550 |
US-$
2,790 |
|
Integration of pump control in vaporizer- or
vaporizer/blender control system;
includes Start/Stop Station,
Explosion-Proof, NEMA 7,9,3R Outdoor Enclosure; Start/Stop
Station; Pilot Light; installed at pump skid. |
US-$
2,664 |
US-$
3,904 |
|
Automatic pump start/stop in response to pressure
in storage tank(s); includes option “integration of pump control
in vaporizer- or
vaporizer/blender control system”; includes Rosemount pressure
transmitter in pump inlet. |
US-$
5,578 |
US-$
6,818 |
|
|
|
|
Motor Starters and Other Options for
Three-Phase Pumps (fits both Blackmer and Corken
Pumps) |
|
Liquid
Transfer Pumps with 3-phase motors always require magnetic motor
starters. All AES magnetic motor starters are configured with contactor,
solid state motor overload protection, service-disconnect function, and
manual reset.
AES Starter Packages will be configured to
match the selected pump size and motor, and are available for indoor
installation, outdoor installation, and explosion-proof Class I, Div 1,
Group D [Flame-Proof] installations. It is recommended that all pumps
are also equipped with a local Start/Stop station that allows pump
control from the pump location. AES Start/Stop stations are configured
with an explosion-proof enclosure (Class I, Div 1, Group D
[Flame-Proof]), green START button, red STOP button, and amber pilot
light (pump ready to be started).
All types can also be integrated into the
vaporizer or vaporizer/blender control system for remote monitoring and
control of the pump operation.
The pump operation can also be automated in
response to the pressure in the storage tanks (pump will start
automatically if tank pressure falls below an adjustable setpoint, and
stays on until the tank pressure has recovered above a second adjustable
setpoint). |
|
|
Description (for Three-Phase Motors) |
Single-Pump |
Dual-Pump |
|
Starter Package, Non-Explosion-Proof; installed in
separate enclosure without
Start/Stop Station;
supplied loose for indoor field installation
(NEMA 1 Indoor Enclosure). |
up to
10 HP |
US-$ 1,923 |
US-$ 3,461 |
over
10 HP |
US-$ 2,307 |
US-$ 4,152 |
|
Starter Package, Non-Explosion-Proof; installed in
separate enclosure with
integrated Start/Stop Station and Pilot Light;
supplied loose for indoor field installation
(NEMA 1 Indoor Enclosure). |
up to
10 HP |
US-$ 2,326 |
US-$ 3,864 |
over
10 HP |
US-$ 2,710 |
US-$ 4,555 |
|
Starter Package, Non-Explosion-Proof; installed in
separate enclosure without
Start/Stop Station;
supplied loose for outdoor field installation
(NEMA 3R Outdoor Enclosure). |
up to
10 HP |
US-$ 2,105 |
US-$ 3,643 |
over
10 HP |
US-$ 2,489 |
US-$ 4,334 |
|
Starter Package, Non-Explosion-Proof; installed in
separate enclosure with
integrated Start/Stop Station and Pilot Light;
supplied loose for outdoor field installation
(NEMA 3R Outdoor Enclosure). |
up to
10 HP |
US-$ 2,508 |
US-$ 4,096 |
over
10 HP |
US-$ 2,892 |
US-$ 4,737 |
|
Starter Package, Explosion-Proof Class I Div 1 Group D
[Flame Proof]; installed in separate enclosure with integrated
Start/Stop Station and
Pilot Light; supplied loose for outdoor field installation (NEMA 7, 9,
3R Ex-Proof Outdoor Enclosure). |
up to
10 HP |
US-$ 4,607 |
US-$ 8,293 |
over
10 HP |
US-$ 5,388 |
US-$ 9,689 |
|
Start/Stop Station, Explosion-Proof Class I Div 1 Group D [Flame Proof];
installed in separate enclosure; green START button; red STOP button;
amber Pilot Light; supplied loose for field installation at pump
location (NEMA 7, 9, 3R Ex-Proof Outdoor Enclosure). |
US-$ 1,550 |
US-$ 2,790 |
|
Start/Stop Station, Explosion-Proof Class I Div 1 Group D [Flame Proof];
installed in separate enclosure; green START button; red STOP button;
amber Pilot Light; and
integrated ESD Station (“Mushroom Button); supplied loose for field
installation at pump location (NEMA 7, 9, 3R Ex-Proof Outdoor
Enclosure). |
US-$ 1,896 |
US-$ 3,136 |
|
Integration of pump control in vaporizer- or vaporizer/blender control
system; includes Start/Stop Station, Explosion-Proof Class I Div 1 Group
D [Flame Proof]; green START button; red STOP button; amber Pilot Light;
installed in separate enclosure at pump skid. |
US-$ 2,664 |
US-$ 3,904 |
|
Automatic pump start/stop in response to pressure in
storage tank(s); includes option “integration of pump control in
vaporizer- or
vaporizer/blender control system”; includes Rosemount pressure
transmitter in pump inlet. |
US-$ 5,578 |
US-$ 6,818 |
|
Installation of Non-Explosion-Proof Motor Starter inside or outside a
Vaporizer Control Room; includes separate conduit entries for power
feed, connection to pump, and connection to Start/Stop Station.
|
US-$ 769 |
US-$ 1,384 |
|
Installation of Explosion-Proof Motor Starter at pump skid; includes
mounting frame for ex-proof starter enclosure; includes conduit
connection between starter enclosure and motor junction box; includes
18-inch flex conduit. |
US-$ 2,347 |
US-$ 4,225 |
|
|
|
|