Pump System Features

  • Capacities from 5 gpm to 150+ gpm
  • Direct-Drive Pumps up to 26 gpm
  • Belt-Driven Pumps 29 gpm and above
  • Skid-mounted
  • Primed and Painted
  • Inlet Strainer
  • Flexible Inlet/Outlet Connections
  • All-welded piping
  • Backpressure Regulator
  • Summer-Bypass
  • Liquid-filled Pressure Gauges
  • Single-Pump Systems
  • Duplex-Pump Systems
  • Blackmer Pumps
  • Corken Pumps
  • US Voltages
  • International Voltages
  • Ex-proof Motors
    Class I, Div. 1, Group D [Flame-Proof]

 

 

Quick-Select Chart for
AES Vaporizers / AES Pumps

Pump Selection Charts:

LPG Transfer Pumps, as the name implies, are used to transfer liquid LPG from the storage tanks to the vaporizer. In systems with venturi LPG/air mixing systems, they are also responsible for maintaining the pressure needed for optimum and efficient function of the venturi mixers.

AES uses pumps from the two leading manufacturers, Blackmer and Corken. All pumps are of "positive displacement" design and use rotary vane pumps with a built-in over-pressure relief valve, designed for continuous use with high reliability.

All pumps are mounted on steel skids, and are primed and painted. They are equipped with constant pressure regulator, strainer, isolation valves, summer bypass loops, liquid filled pressure gauges, and other components that are required for safe operation.

All systems are supplied with an explosion proof motor to meet Class I, Div. 1, Group D [Flame-Proof] requirements, and are available for 60Hz service or for 50Hz service and for various voltages. Smaller pumps are for single phase service. Larger pumps are for 3-phase service and require magnetic motor starters.

When sizing a pump system, the nominal pump capacity should be approximately twice the nominal capacity of the LP or LP/Air system. Nominal pump capacities may vary with type of LPG, ambient conditions, available electric service, required discharge pressure, and other factors.

Blackmer pumps up to model AEP-12B, and Corken pumps up to model AEP-18C, are direct-drive pumps (electric motor directly coupled to pump). Larger pumps are belt-driven.

The purpose of Duplex Pump Systems is to provide maximum redundancy. They are therefore manufactured as individual pumps that only share a common skid. All bypass and isolation valves exist in duplicate and allow using the pumps in any combination: Pump 1, Pump 2, or Pump 1 and Pump 2 together. Each pump can be completely isolated so that maintenance and repair work on this pump does not affect the other pump, or the system availability.

Magnetic motor starters can be supplied either as separate components, installed on the pump skid, or integrated with the system controls. If pump systems are integrated with the vaporizer or vaporizer/blender controls, a start/stop station in an ex-proof enclosure is installed directly at the pump skid and provides local pump control.

Integrated pumps can also be equipped with an automatic start/stop function in response to the pressure in the storage tank(s). The price adder for these options is shown below (in the “Motor Starters and other Options” section).

 

Corken Pumps
Selection Chart
  
60Hz
 
All prices and specifications are
subject to change without notice.

Direct-Driven Belt-Driven
CF12

AEP-
05C

CF13

AEP-
07C

FF14

AEP-
11C

FF150

AEP-
18C

Z2000

AEP-
32C

Z3500

AEP-
42C

Z3500

AEP-
53C

Z3500

AEP-
68C

Z4500

AEP-
98C

Single Pump System US-$
14,323
US-$
14,615
US-$
15,379
US-$
17,160
US-$
19,826
US-$
31,295
US-$
32,696
US-$
40,663
US-$
51,032
Duplex Pump System US-$
28,933
US-$
29,523
US-$
31,066
US-$
34,664
US-$
40,049
US-$
63,216
US-$
66,046
US-$
82,140
US-$
103,085

Maximum Vaporizer Capacity [gph]
Maximum Vaporizer Capacity [kg/h]
(based on 100psi / 7 bar discharge)

Find "your" LPG type and the sample operating conditions in the column on the far-left.
Move to the right until the shown value is equal to, or greater than, the capacity of the vaporizer that is to be supplied by the pump.
Move up to identify the AES Pump Model Number.

   HD-5 Propane
  
Min. Temperature   0°F / -18°C
   ΔP  78 psi / 5.4 bar
288
558
408
790
648
1254
1080
2091
1920
3717
2520
4878
3192
6179
4056
7852
5856
11336
   HD-5 Propane
  
Min. Temperature   -40F / -40°C
   ΔP  99 psi / 6.8 bar
168
325
312
604
480
929
1008
1951
1872
3624
2280
4414
3000
5807
3936
7619
5784
11197
   LPG with 50% Propane/50%Butane
  
Min. Temperature   32°F / 0°C
   ΔP  74 psi / 5.1 bar
216
443
312
640
504
1034
696
1428
1176
2413
1656
3398
2064
4236
2520
5171
3576
7338
  LPG with 50% Propane/50%Butane
  
Min. Temperature   15°F / -10°C
   ΔP  82 psi / 5.7 bar
192
394
288
591
456
936
696
1428
1176
2413
1584
3251
1992
4088
2496
5122
3552
7289
  LPG with 30% Propane/70%Butane
  
Min. Temperature   32°F / 0°C
   ΔP  84 psi / 5.8 bar
144
303
216
454
336
707
480
1010
792
1666
1104
2323
1128
2373
1680
3534
2376
4999
Electric Motor 220V 60Hz 220V 60Hz  or
460V 60Hz
460V 60Hz
   Motor Type Single-Phase

3-Phase
(all 3-phase motors require magnetic starters and overload protection)

   Motor Protection

Class I, Div 1, Group D  (Flame Proof)

   Motor Size [hp] 2 3 5 7.5 7.5 10 15 20 25
   Motor RPM 3450 3450 3450 3450 750 520 640 780 520
Pump Connections

All pump body connections and all on-skid component connections are 300# RF ANSI.
All pump skid connections are 300# RF ANSI or DIN PN40 (PN25 for DN100 and above).

   Pump Body, Inlet 1.5" 1.5" 1.5" 1.5" 2" 3" 3" 3" 4"
   Pump Body, Outlet 1" 1" 1" 1" 2" 3" 3" 3" 4"
   Pump Skid, Inlet 2"
DN50
2"
DN50
2"
DN50
2"
DN50
3"
DN80
4"
DN100
4"
DN100
4"
DN100
6"
DN150
   Pump Skid, Outlet 1"
DN25
1"
DN25
1"
DN25
1"
DN25
2"
DN50
3"
DN80
3"
DN80
3"
DN80
3"
DN80
  

Corken Pumps
Selection Chart
  
50Hz
 
All prices and specifications are
subject to change without notice.

Direct-Driven Belt-Driven
CF12

AEP-
05C

CF13

AEP-
07C

FF075

AEP-
11C

FF150

AEP-
18C

Z2000

AEP-
32C

Z3500

AEP-
42C

Z3500

AEP-
53C

Z3500

AEP-
68C

Z4500

AEP-
98C

Single Pump System (US-$)   US-$
15,243
US-$
16,500
US-$
17,758
US-$
20,455
US-$
32,058
US-$
33,472
US-$
41,643
US-$
52,015
Duplex Pump System (US-$)   US-$
30,791
US-$
33,330
US-$
35,872
US-$
41,320
US-$
64,758
US-$
67,414
US-$
84,119
US-$
105,071

Maximum Vaporizer Capacity [gph]
Maximum Vaporizer Capacity [kg/h]
(based on 100psi / 7 bar discharge)

Find "your" LPG type and the sample operating conditions in the column on the far-left.
Move to the right until the shown value is equal to, or greater than, the capacity of the vaporizer that is to be supplied by the pump.
Move up to identify the AES Pump Model Number.

   HD-5 Propane
  
Min. Temperature   0°F / -18°C
   ΔP  78 psi / 5.4 bar
n/a 192
372
528
1022
864
1673
1920
3717
2520
4878
3192
6179
4056
7852
5856
11336
   HD-5 Propane
  
Min. Temperature   -40F / -40°C
   ΔP  99 psi / 6.8 bar
n/a 72
139
432
836
768
1487
1872
3624
2280
4414
3000
5807
3936
7619
5784
11197
   LPG with 50% Propane/50%Butane
  
Min. Temperature   32°F / 0°C
   ΔP  74 psi / 5.1 bar
n/a 192
394
384
788
600
1231
1176
2413
1656
3398
2064
4236
2520
5171
3576
7338
  LPG with 50% Propane/50%Butane
  
Min. Temperature   15°F / -10°C
   ΔP  82 psi / 5.7 bar
n/a 168
345
360
739
576
1182
1176
2413
1584
3251
1992
4088
2496
5122
3552
7289
  LPG with 30% Propane/70%Butane
  
Min. Temperature   32°F / 0°C
   ΔP  84 psi / 5.8 bar
n/a 120
252
240
505
384
808
792
1666
1104
2323
1128
2373
1680
3534
2376
4999
Electric Motor 230V 50Hz 400/415V 50Hz
   Motor Type Single-Phase

3-Phase
(all 3-phase motors require magnetic starters and overload protection)

   Motor Protection

Class I, Div 1, Group D  (Flame Proof)

   Motor Size [hp] n/a 3 5 7.5 7.5 10 15 20 25
   Motor RPM n/a 2880 2880 2880 750 520 640 780 520
Pump Connections

All pump body connections and all on-skid component connections are 300# RF ANSI.
All pump skid connections are 300# RF ANSI or DIN PN40 (PN25 for DN100 and above).

   Pump Body, Inlet n/a 1.5" 1.5" 1.5" 2" 3" 3" 3" 4"
   Pump Body, Outlet n/a 1" 1" 1" 2" 3" 3" 3" 4"
   Pump Skid, Inlet n/a 2"
DN50
2"
DN50
2"
DN50
3"
DN80
4"
DN100
4"
DN100
4"
DN100
6"
DN150
   Pump Skid, Outlet n/a 1"
DN25
1"
DN25
1"
DN25
2"
DN50
3"
DN80
3"
DN80
3"
DN80
3"
DN80
  

Blackmer Pumps
Selection Chart
  
60Hz 
All prices and specifications are
subject to change without notice.

Direct-Driven Belt-Driven
LGF1

AEP-
03B

LGF1P

AEP-
04B

LGL1.25

AEP-
08B

LGL1.5

AEP-
12B

LGL2

AEP-
18B

LGL3

AEP-
28B

LGL3

AEP-
37B

LGL4

AEP-
66B

LGL4

AEP-
85B

Single Pump System US-$
14,065
US-$
14,426
US-$
15,400
US-$
17,679
US-$
20,146
US-$
31,806
US-$
33,315
US-$
48,400
US-$
52,800
Duplex Pump System US-$
28,412
US-$
29,141
US-$
31,108
US-$
35,712
US-$
40,695
US-$
64,249
US-$
67,297
US-$
97,768
US-$
106,656

Maximum Vaporizer Capacity [gph]
Maximum Vaporizer Capacity [kg/h]
(based on 100psi / 7 bar discharge)

Find "your" LPG type and the sample operating conditions in the column on the far-left.
Move to the right until the shown value is equal to, or greater than, the capacity of the vaporizer that is to be supplied by the pump.
Move up to identify the AES Pump Model Number.

   HD-5 Propane
  
Min. Temperature   0°F / -18°C
   ΔP  78 psi / 5.4 bar
168
325
264
511
456
883
720
1394
1104
2137
1656
3206
2208
4274
3960
7666
5088
9850
   HD-5 Propane
  
Min. Temperature   -40F / -40°C
   ΔP  99 psi / 6.8 bar
144
279
240
465
432
836
696
1347
1008
1951
1440
2788
1992
3856
3480
6737
4752
9199
   LPG with 50% Propane/50%Butane
  
Min. Temperature   32°F / 0°C
   ΔP  74 psi / 5.1 bar
120
246
192
394
288
591
456
936
744
1527
1128
2315
1440
2955
2640
5418
3336
6846
  LPG with 50% Propane/50%Butane
  
Min. Temperature   15°F / -10°C
   ΔP  82 psi / 5.7 bar
120
246
168
345
288
591
456
936
696
1428
1080
2216
1416
2906
2520
5171
3240
6649
  LPG with 30% Propane/70%Butane
  
Min. Temperature   32°F / 0°C
   ΔP  84 psi / 5.8 bar
72
151
120
252
192
404
312
656
480
1010
768
1616
960
2020
1752
3686
2232
4696
Electric Motor 220V 60Hz 220 or 460V 60Hz 460V 60Hz
   Motor Type Single-Phase

3-Phase
(all 3-phase motors require magnetic starters and overload protection)

   Motor Protection

Class I, Div 1, Group D  (Flame Proof)

   Motor Size [hp] 1 1.5 3 5 7.5 10 15 20 25
   Motor RPM 1750 1750 1750 1750 520 420 520 420 520
Pump Connections

All pump body connections and all on-skid component connections are 300# RF ANSI.
All pump skid connections are 300# RF ANSI or DIN PN40 (PN25 for DN100 and above).

   Pump Body, Inlet 1" 1" 1.25" 1.5" 2" 3" 3" 4" 4"
   Pump Body, Outlet 1" 1" 1.25" 1.5" 2" 3" 3" 4" 4"
   Pump Skid, Inlet 1.5"
DN40
1.5"
DN40
2"
DN50
2"
DN50
3"
DN80
4"
DN100
4"
DN100
6"
DN150
6"
DN150
   Pump Skid, Outlet 1"
DN25
1"
DN25
1"
DN25
1.5"
DN40
2"
DN50
3"
DN80
3"
DN80
4"
DN100
4"
DN100
   

Blackmer Pumps
Selection Chart
  
50Hz 
All prices and specifications are
subject to change without notice.

Direct-Driven Belt-Driven
LGF1

AEP-
03B

LGF1P

AEP-
04B

LGL1.25

AEP-
08B

LGL1.5

AEP-
12B

LGL2

AEP-
18B

LGL3

AEP-
28B

LGL3

AEP-
37B

LGL4

AEP-
66B

LGL4

AEP-
85B

Single Pump System US-$
14,693
US-$
15,055
US-$
16,029
US-$
18,386
US-$
20,775
US-$
32,529
US-$
34,258
US-$
49,972
US-$
54,215
Duplex Pump System US-$
29,680
US-$
30,412
US-$
32,379
US-$
37,140
US-$
41,966
US-$
65,709
US-$
69,202
US-$
100,944
US-$
109,915

Maximum Vaporizer Capacity [gph]
Maximum Vaporizer Capacity [kg/h]
(based on 100psi / 7 bar discharge)

Find "your" LPG type and the sample operating conditions in the column on the far-left.
Move to the right until the shown value is equal to, or greater than, the capacity of the vaporizer that is to be supplied by the pump.
Move up to identify the AES Pump Model Number.

   HD-5 Propane
  
Min. Temperature   0°F / -18°C
   ΔP  78 psi / 5.4 bar
120
232
192
372
384
743
576
1115
1104
2137
1656
3206
2208
4274
3960
7566
5088
9850
   HD-5 Propane
  
Min. Temperature   -40F / -40°C
   ΔP  99 psi / 6.8 bar
96
186
168
325
336
650
552
1069
1008
1951
1440
2788
1992
3856
3480
6737
4752
9199
   LPG with 50% Propane/50%Butane
  
Min. Temperature   32°F / 0°C
   ΔP  74 psi / 5.1 bar
120
246
144
296
264
542
384
788
744
1527
1128
2315
1440
2955
2640
5418
3336
6846
  LPG with 50% Propane/50%Butane
  
Min. Temperature   15°F / -10°C
   ΔP  82 psi / 5.7 bar
120
246
144
296
240
493
360
739
696
1428
1080
2216
1416
2906
2520
5171
3240
6649
  LPG with 30% Propane/70%Butane
  
Min. Temperature   32°F / 0°C
   ΔP  84 psi / 5.8 bar
72
151
96
202
168
353
240
505
480
1010
768
1616
960
2020
1752
3686
2232
4696
Electric Motor 230V 50Hz 400/415V 50Hz
   Motor Type Single-Phase

3-Phase
(all 3-phase motors require magnetic starters and overload protection)

   Motor Protection

Class I, Div 1, Group D  (Flame Proof)

   Motor Size [hp] 1 1.5 3 5 7.5 10 15 20 25
   Motor RPM 1450 1450 1450 1450 420 350 420 350 420
Pump Connections

All pump body connections and all on-skid component connections are 300# RF ANSI.
All pump skid connections are 300# RF ANSI or DIN PN40 (PN25 for DN100 and above).

   Pump Body, Inlet 1" 1" 1.25" 1.5" 2" 3" 3" 4" 4"
   Pump Body, Outlet 1" 1" 1.25" 1.5" 2" 3" 3" 4" 4"
   Pump Skid, Inlet 1.5"
DN40
1.5"
DN40
2"
DN50
2"
DN50
3"
DN80
4"
DN100
4"
DN100
6"
DN150
6"
DN150
   Pump Skid, Outlet 1"
DN25
1"
DN25
1"
DN25
1.5"
DN40
2"
DN50
3"
DN80
3"
DN80
4"
DN100
4"
DN100
 

Motor Starters and Other Options for Single-Phase Pumps (fits both Blackmer and Corken Pumps)

Liquid Transfer Pumps with single-phase motors can be supplied with a simple, explosion-proof ON/OFF switch that is integrated into the junction box directly at the pump motor. If the pump control is desired to be integrated with the vaporizer- or vaporizer/blender control system (for example to facilitate remote monitoring and control), pumps with single-phase motors can also be equipped with contactors.
 
It is recommended that contactor-equipped pumps are also equipped with a local Start/Stop station that allows pump control from the pump location. AES Start/Stop stations are configured with an explosion-proof enclosure (Class I, Div 1, Group D [Flame-Proof]), green START button, red STOP button, and amber pilot light (pump ready to be started).
  
The operation of single-phase pumps with contactors can also be automated in response to the pressure in the storage tanks (pump will start automatically if tank pressure falls below an adjustable setpoint, and stays on until the tank pressure has recovered above a second adjustable setpoint).
 

Description (for Single-Phase Motors) Single-Pump Dual-Pump

Pump Contactor for single-phase pumps, max. motor size 5HP; installed in vaporizer- or vaporizer/blender control panel; terminals for AC feed, pump connection, and control voltage.

US-$ 769 US-$ 1,385

Pump Contactor for single-phase pumps, max. motor size 5HP; installed in separate enclosure; supplied loose for indoor field installation (NEMA 1).  

US-$ 1,077 US-$ 1,938

Pump Contactor for single-phase pumps, max. motor size 5HP; installed in separate enclosure; supplied loose for outdoor field installation (NEMA 3R).

US-$ 1,399 US-$ 2,260

Start/Stop Station, Explosion-Proof Class I Div 1 Group D [Flame Proof]; installed in separate enclosure; green START button; red STOP button; amber Pilot Light; supplied loose for field installation at pump location (NEMA 7, 9, 3R Ex-Proof Outdoor Enclosure).

US-$ 1,550 US-$ 2,790

Integration of pump control in vaporizer- or vaporizer/blender control system; includes Start/Stop Station, Explosion-Proof, NEMA 7,9,3R Outdoor Enclosure; Start/Stop Station; Pilot Light; installed at pump skid.

US-$ 2,664 US-$ 3,904

Automatic pump start/stop in response to pressure in storage tank(s); includes option “integration of pump control in vaporizer- or vaporizer/blender control system”; includes Rosemount pressure transmitter in pump inlet.

US-$ 5,578 US-$ 6,818
  

Motor Starters and Other Options for Three-Phase Pumps (fits both Blackmer and Corken Pumps)

Liquid Transfer Pumps with 3-phase motors always require magnetic motor starters. All AES magnetic motor starters are configured with contactor, solid state motor overload protection, service-disconnect function, and manual reset.

AES Starter Packages will be configured to match the selected pump size and motor, and are available for indoor installation, outdoor installation, and explosion-proof Class I, Div 1, Group D [Flame-Proof] installations. It is recommended that all pumps are also equipped with a local Start/Stop station that allows pump control from the pump location. AES Start/Stop stations are configured with an explosion-proof enclosure (Class I, Div 1, Group D [Flame-Proof]), green START button, red STOP button, and amber pilot light (pump ready to be started).

All types can also be integrated into the vaporizer or vaporizer/blender control system for remote monitoring and control of the pump operation.

The pump operation can also be automated in response to the pressure in the storage tanks (pump will start automatically if tank pressure falls below an adjustable setpoint, and stays on until the tank pressure has recovered above a second adjustable setpoint).

Description (for Three-Phase Motors)

Single-Pump Dual-Pump

Starter Package, Non-Explosion-Proof; installed in separate enclosure without Start/Stop Station; supplied loose for indoor field installation
(NEMA 1 Indoor Enclosure).

up to
10 HP
US-$ 1,923 US-$ 3,461
over
10 HP
US-$ 2,307 US-$ 4,152

Starter Package, Non-Explosion-Proof; installed in separate enclosure with integrated Start/Stop Station and Pilot Light; supplied loose for indoor field installation
(NEMA 1 Indoor Enclosure).

up to
10 HP
US-$ 2,326 US-$ 3,864
over
10 HP
US-$ 2,710 US-$ 4,555

Starter Package, Non-Explosion-Proof; installed in separate enclosure without Start/Stop Station; supplied loose for outdoor field installation
(NEMA 3R Outdoor Enclosure).

up to
10 HP
US-$ 2,105 US-$ 3,643
over
10 HP
US-$ 2,489 US-$ 4,334

Starter Package, Non-Explosion-Proof; installed in separate enclosure with integrated Start/Stop Station and Pilot Light; supplied loose for outdoor field installation
(NEMA 3R Outdoor Enclosure).

up to
10 HP
US-$ 2,508 US-$ 4,096
over
10 HP
US-$ 2,892 US-$ 4,737

Starter Package, Explosion-Proof Class I Div 1 Group D [Flame Proof]; installed in separate enclosure with integrated Start/Stop Station and Pilot Light; supplied loose for outdoor field installation (NEMA 7, 9, 3R Ex-Proof Outdoor Enclosure).

up to
10 HP
US-$ 4,607 US-$ 8,293
over
10 HP
US-$ 5,388 US-$ 9,689
Start/Stop Station, Explosion-Proof Class I Div 1 Group D [Flame Proof]; installed in separate enclosure; green START button; red STOP button; amber Pilot Light; supplied loose for field installation at pump location (NEMA 7, 9, 3R Ex-Proof Outdoor Enclosure). US-$ 1,550 US-$ 2,790
Start/Stop Station, Explosion-Proof Class I Div 1 Group D [Flame Proof]; installed in separate enclosure; green START button; red STOP button; amber Pilot Light; and integrated ESD Station (“Mushroom Button); supplied loose for field installation at pump location (NEMA 7, 9, 3R Ex-Proof Outdoor Enclosure). US-$ 1,896 US-$ 3,136
Integration of pump control in vaporizer- or vaporizer/blender control system; includes Start/Stop Station, Explosion-Proof Class I Div 1 Group D [Flame Proof]; green START button; red STOP button; amber Pilot Light; installed in separate enclosure at pump skid. US-$ 2,664 US-$ 3,904

Automatic pump start/stop in response to pressure in storage tank(s); includes option “integration of pump control in vaporizer- or vaporizer/blender control system”; includes Rosemount pressure transmitter in pump inlet.  

US-$ 5,578 US-$ 6,818
Installation of Non-Explosion-Proof Motor Starter inside or outside a Vaporizer Control Room; includes separate conduit entries for power feed, connection to pump, and connection to Start/Stop Station. US-$ 769 US-$ 1,384
Installation of Explosion-Proof Motor Starter at pump skid; includes mounting frame for ex-proof starter enclosure; includes conduit connection between starter enclosure and motor junction box; includes 18-inch flex conduit. US-$ 2,347 US-$ 4,225
 

HOME | PRODUCTS | VAPORIZERS | MIXERS/BLENDERS | PACKAGED SYSTEMS | ACCESSORIES | PRODUCT APPROVALS | PRICE LISTS
DOWNLOADS | TECHNOLOGY | LPG PROPERTIES | SYSTEM SIZING WORKSHEET | NEWS | AES COMPANY PROFILE | AES LOCATION
AES CONTACTS | LITERATURE REQUEST | SEARCH | SITE MAP GraviBlend-3 GRAVITOMETER OTHER BLENDING APPLICATIONS