Corken Pumps
Selection Chart
60Hz
All prices and specifications are
subject to change without notice. |
Direct-Driven |
Belt-Driven |
|
CF12
AEP-
05C |
CF13
AEP-
07C |
FF14
AEP-
11C |
FF150
AEP-
18C |
Z2000
AEP-
32C |
Z3500
AEP-
42C |
Z3500
AEP-
53C |
Z3500
AEP-
68C |
Z4500
AEP-
98C |
|
Maximum Vaporizer
Capacity [gph]
Maximum Vaporizer Capacity [kg/h]
(based on 100psi / 7 bar
discharge) |
Find "your" LPG type and the sample
operating conditions in the column on the far-left.
Move to the right until the shown value is equal to, or greater than,
the capacity of the vaporizer that is to be supplied by the pump.
Move up to identify the AES Pump Model Number. |
HD-5 Propane
Min.
Temperature 0°F / -18°C
ΔP 78 psi / 5.4 bar |
288
558 |
408
790 |
648
1254 |
1080
2091 |
1920
3717 |
2520
4878 |
3192
6179 |
4056
7852 |
5856
11336 |
HD-5 Propane
Min.
Temperature -40F / -40°C
ΔP 99 psi / 6.8 bar |
168
325 |
312
604 |
480
929 |
1008
1951 |
1872
3624 |
2280
4414 |
3000
5807 |
3936
7619 |
5784
11197 |
LPG with 50% Propane/50%Butane
Min.
Temperature 32°F / 0°C
ΔP 74 psi / 5.1 bar |
216
443 |
312
640 |
504
1034 |
696
1428 |
1176
2413 |
1656
3398 |
2064
4236 |
2520
5171 |
3576
7338 |
LPG
with 50% Propane/50%Butane
Min.
Temperature 15°F / -10°C
ΔP 82 psi / 5.7 bar |
192
394 |
288
591 |
456
936 |
696
1428 |
1176
2413 |
1584
3251 |
1992
4088 |
2496
5122 |
3552
7289 |
LPG
with 30% Propane/70%Butane
Min.
Temperature 32°F / 0°C
ΔP 84 psi / 5.8 bar |
144
303 |
216
454 |
336
707 |
480
1010 |
792
1666 |
1104
2323 |
1128
2373 |
1680
3534 |
2376
4999 |
| Electric
Motor |
220V 60Hz |
220V 60Hz or
460V 60Hz |
460V 60Hz |
|
Motor Type |
Single-Phase |
3-Phase
(all 3-phase motors require magnetic starters and overload protection)
|
|
Motor Protection |
Class I, Div 1, Group
D (Flame Proof) |
|
Motor Size [hp] |
2 |
3 |
5 |
7.5 |
7.5 |
10 |
15 |
20 |
25 |
|
Motor RPM |
3450 |
3450 |
3450 |
3450 |
750 |
520 |
640 |
780 |
520 |
| Pump
Connections |
All pump body
connections and all on-skid component connections are 300# RF ANSI.
All pump skid connections are 300# RF ANSI or DIN PN40 (PN25 for DN100
and above). |
|
Pump Body, Inlet |
1.5" |
1.5" |
1.5" |
1.5" |
2" |
3" |
3" |
3" |
4" |
|
Pump Body, Outlet |
1" |
1" |
1" |
1" |
2" |
3" |
3" |
3" |
4" |
|
Pump Skid, Inlet |
2"
DN50 |
2"
DN50 |
2"
DN50 |
2"
DN50 |
3"
DN80 |
4"
DN100 |
4"
DN100 |
4"
DN100 |
6"
DN150 |
|
Pump Skid, Outlet |
1"
DN25 |
1"
DN25 |
1"
DN25 |
1"
DN25 |
2"
DN50 |
3"
DN80 |
3"
DN80 |
3"
DN80 |
3"
DN80 |
|
|
|
Corken Pumps
Selection Chart
50Hz
All prices and specifications are
subject to change without notice. |
Direct-Driven |
Belt-Driven |
|
CF12
AEP-
05C |
CF13
AEP-
07C |
FF075
AEP-
11C |
FF150
AEP-
18C |
Z2000
AEP-
32C |
Z3500
AEP-
42C |
Z3500
AEP-
53C |
Z3500
AEP-
68C |
Z4500
AEP-
98C |
|
Maximum Vaporizer Capacity [gph]
Maximum Vaporizer Capacity [kg/h]
(based on 100psi / 7 bar
discharge)
|
Find "your" LPG type and the sample
operating conditions in the column on the far-left.
Move to the right until the shown value is equal to, or greater than,
the capacity of the vaporizer that is to be supplied by the pump.
Move up to identify the AES Pump Model Number. |
HD-5 Propane
Min.
Temperature 0°F / -18°C
ΔP 78 psi / 5.4 bar |
n/a |
192
372 |
528
1022 |
864
1673 |
1920
3717 |
2520
4878 |
3192
6179 |
4056
7852 |
5856
11336 |
HD-5 Propane
Min.
Temperature -40F / -40°C
ΔP 99 psi / 6.8 bar |
n/a |
72
139 |
432
836 |
768
1487 |
1872
3624 |
2280
4414 |
3000
5807 |
3936
7619 |
5784
11197 |
LPG with 50% Propane/50%Butane
Min.
Temperature 32°F / 0°C
ΔP 74 psi / 5.1 bar |
n/a |
192
394 |
384
788 |
600
1231 |
1176
2413 |
1656
3398 |
2064
4236 |
2520
5171 |
3576
7338 |
LPG
with 50% Propane/50%Butane
Min.
Temperature 15°F / -10°C
ΔP 82 psi / 5.7 bar |
n/a |
168
345 |
360
739 |
576
1182 |
1176
2413 |
1584
3251 |
1992
4088 |
2496
5122 |
3552
7289 |
LPG
with 30% Propane/70%Butane
Min.
Temperature 32°F / 0°C
ΔP 84 psi / 5.8 bar |
n/a |
120
252 |
240
505 |
384
808 |
792
1666 |
1104
2323 |
1128
2373 |
1680
3534 |
2376
4999 |
| Electric
Motor |
230V 50Hz |
400/415V 50Hz |
|
Motor Type |
Single-Phase |
3-Phase
(all 3-phase motors require magnetic starters and overload protection)
|
|
Motor Protection |
Class I, Div 1, Group
D (Flame Proof) |
|
Motor Size [hp] |
n/a |
3 |
5 |
7.5 |
7.5 |
10 |
15 |
20 |
25 |
|
Motor RPM |
n/a |
2880 |
2880 |
2880 |
750 |
520 |
640 |
780 |
520 |
| Pump
Connections |
All pump body
connections and all on-skid component connections are 300# RF ANSI.
All pump skid connections are 300# RF ANSI or DIN PN40 (PN25 for DN100
and above). |
|
Pump Body, Inlet |
n/a |
1.5" |
1.5" |
1.5" |
2" |
3" |
3" |
3" |
4" |
|
Pump Body, Outlet |
n/a |
1" |
1" |
1" |
2" |
3" |
3" |
3" |
4" |
|
Pump Skid, Inlet |
n/a |
2"
DN50 |
2"
DN50 |
2"
DN50 |
3"
DN80 |
4"
DN100 |
4"
DN100 |
4"
DN100 |
6"
DN150 |
|
Pump Skid, Outlet |
n/a |
1"
DN25 |
1"
DN25 |
1"
DN25 |
2"
DN50 |
3"
DN80 |
3"
DN80 |
3"
DN80 |
3"
DN80 |
|
|
|
Blackmer
Pumps
Selection Chart
60Hz
All prices and specifications are
subject to change without notice. |
Direct-Driven |
Belt-Driven |
|
LGF1
AEP-
03B |
LGF1P
AEP-
04B |
LGL1.25
AEP-
08B |
LGL1.5
AEP-
12B |
LGL2
AEP-
18B |
LGL3
AEP-
28B |
LGL3
AEP-
37B |
LGL4
AEP-
66B |
LGL4
AEP-
85B |
|
Maximum Vaporizer Capacity [gph]
Maximum Vaporizer Capacity [kg/h]
(based on 100psi / 7 bar
discharge)
|
Find "your" LPG type and the sample
operating conditions in the column on the far-left.
Move to the right until the shown value is equal to, or greater than,
the capacity of the vaporizer that is to be supplied by the pump.
Move up to identify the AES Pump Model Number. |
HD-5 Propane
Min.
Temperature 0°F / -18°C
ΔP 78 psi / 5.4 bar |
168
325 |
264
511 |
456
883 |
720
1394 |
1104
2137 |
1656
3206 |
2208
4274 |
3960
7666 |
5088
9850 |
HD-5 Propane
Min.
Temperature -40F / -40°C
ΔP 99 psi / 6.8 bar |
144
279 |
240
465 |
432
836 |
696
1347 |
1008
1951 |
1440
2788 |
1992
3856 |
3480
6737 |
4752
9199 |
LPG with 50% Propane/50%Butane
Min.
Temperature 32°F / 0°C
ΔP 74 psi / 5.1 bar |
120
246 |
192
394 |
288
591 |
456
936 |
744
1527 |
1128
2315 |
1440
2955 |
2640
5418 |
3336
6846 |
LPG
with 50% Propane/50%Butane
Min.
Temperature 15°F / -10°C
ΔP 82 psi / 5.7 bar |
120
246 |
168
345 |
288
591 |
456
936 |
696
1428 |
1080
2216 |
1416
2906 |
2520
5171 |
3240
6649 |
LPG
with 30% Propane/70%Butane
Min.
Temperature 32°F / 0°C
ΔP 84 psi / 5.8 bar |
72
151 |
120
252 |
192
404 |
312
656 |
480
1010 |
768
1616 |
960
2020 |
1752
3686 |
2232
4696 |
| Electric
Motor |
220V 60Hz |
220 or 460V 60Hz |
460V 60Hz |
|
Motor Type |
Single-Phase |
3-Phase
(all 3-phase motors require magnetic starters and overload protection)
|
|
Motor Protection |
Class I, Div 1, Group
D (Flame Proof) |
|
Motor Size [hp] |
1 |
1.5 |
3 |
5 |
7.5 |
10 |
15 |
20 |
25 |
|
Motor RPM |
1750 |
1750 |
1750 |
1750 |
520 |
420 |
520 |
420 |
520 |
| Pump
Connections |
All pump body
connections and all on-skid component connections are 300# RF ANSI.
All pump skid connections are 300# RF ANSI or DIN PN40 (PN25 for DN100
and above). |
|
Pump Body, Inlet |
1" |
1" |
1.25" |
1.5" |
2" |
3" |
3" |
4" |
4" |
|
Pump Body, Outlet |
1" |
1" |
1.25" |
1.5" |
2" |
3" |
3" |
4" |
4" |
|
Pump Skid, Inlet |
1.5"
DN40 |
1.5"
DN40 |
2"
DN50 |
2"
DN50 |
3"
DN80 |
4"
DN100 |
4"
DN100 |
6"
DN150 |
6"
DN150 |
|
Pump Skid, Outlet |
1"
DN25 |
1"
DN25 |
1"
DN25 |
1.5"
DN40 |
2"
DN50 |
3"
DN80 |
3"
DN80 |
4"
DN100 |
4"
DN100 |
|
|
|
Blackmer
Pumps
Selection Chart
50Hz
All prices and specifications are
subject to change without notice. |
Direct-Driven |
Belt-Driven |
|
LGF1
AEP-
03B |
LGF1P
AEP-
04B |
LGL1.25
AEP-
08B |
LGL1.5
AEP-
12B |
LGL2
AEP-
18B |
LGL3
AEP-
28B |
LGL3
AEP-
37B |
LGL4
AEP-
66B |
LGL4
AEP-
85B |
|
Maximum Vaporizer Capacity [gph]
Maximum Vaporizer Capacity [kg/h]
(based on 100psi / 7 bar
discharge)
|
Find "your" LPG type and the sample
operating conditions in the column on the far-left.
Move to the right until the shown value is equal to, or greater than,
the capacity of the vaporizer that is to be supplied by the pump.
Move up to identify the AES Pump Model Number. |
HD-5 Propane
Min.
Temperature 0°F / -18°C
ΔP 78 psi / 5.4 bar |
120
232 |
192
372 |
384
743 |
576
1115 |
1104
2137 |
1656
3206 |
2208
4274 |
3960
7566 |
5088
9850 |
HD-5 Propane
Min.
Temperature -40F / -40°C
ΔP 99 psi / 6.8 bar |
96
186 |
168
325 |
336
650 |
552
1069 |
1008
1951 |
1440
2788 |
1992
3856 |
3480
6737 |
4752
9199 |
LPG with 50% Propane/50%Butane
Min.
Temperature 32°F / 0°C
ΔP 74 psi / 5.1 bar |
120
246 |
144
296 |
264
542 |
384
788 |
744
1527 |
1128
2315 |
1440
2955 |
2640
5418 |
3336
6846 |
LPG
with 50% Propane/50%Butane
Min.
Temperature 15°F / -10°C
ΔP 82 psi / 5.7 bar |
120
246 |
144
296 |
240
493 |
360
739 |
696
1428 |
1080
2216 |
1416
2906 |
2520
5171 |
3240
6649 |
LPG
with 30% Propane/70%Butane
Min.
Temperature 32°F / 0°C
ΔP 84 psi / 5.8 bar |
72
151 |
96
202 |
168
353 |
240
505 |
480
1010 |
768
1616 |
960
2020 |
1752
3686 |
2232
4696 |
| Electric
Motor |
230V 50Hz |
400/415V 50Hz |
|
Motor Type |
Single-Phase |
3-Phase
(all 3-phase motors require magnetic starters and overload protection)
|
|
Motor Protection |
Class I, Div 1, Group
D (Flame Proof) |
|
Motor Size [hp] |
1 |
1.5 |
3 |
5 |
7.5 |
10 |
15 |
20 |
25 |
|
Motor RPM |
1450 |
1450 |
1450 |
1450 |
420 |
350 |
420 |
350 |
420 |
| Pump
Connections |
All pump body
connections and all on-skid component connections are 300# RF ANSI.
All pump skid connections are 300# RF ANSI or DIN PN40 (PN25 for DN100
and above). |
|
Pump Body, Inlet |
1" |
1" |
1.25" |
1.5" |
2" |
3" |
3" |
4" |
4" |
|
Pump Body, Outlet |
1" |
1" |
1.25" |
1.5" |
2" |
3" |
3" |
4" |
4" |
|
Pump Skid, Inlet |
1.5"
DN40 |
1.5"
DN40 |
2"
DN50 |
2"
DN50 |
3"
DN80 |
4"
DN100 |
4"
DN100 |
6"
DN150 |
6"
DN150 |
|
Pump Skid, Outlet |
1"
DN25 |
1"
DN25 |
1"
DN25 |
1.5"
DN40 |
2"
DN50 |
3"
DN80 |
3"
DN80 |
4"
DN100 |
4"
DN100 |